--    Copyright 2010 Scientific Atlanta, A Cisco Company                                   
--    All Rights Reserved                                                   
--    No portions of this material may be reproduced in any
--    form without the written permission of:                                                
--             Scientific Atlanta, A Cisco Company                                          
--             5030 Sugarloaf Pkwy                                     
--             Lawrenceville, Georgia 30044                                    
--                                                                          
--**************************************************************************

SA-MTA-MIB DEFINITIONS ::= BEGIN
IMPORTS
        MODULE-IDENTITY, 
        OBJECT-TYPE,
        enterprises, 
        Integer32,
        Unsigned32
                FROM SNMPv2-SMI
        ifIndex
                FROM IF-MIB
        SnmpAdminString 
                FROM SNMP-FRAMEWORK-MIB
        TruthValue,
        DateAndTime
                FROM SNMPv2-TC ;
                
sa           OBJECT IDENTIFIER ::= { enterprises 1429 }
saVoip       OBJECT IDENTIFIER ::= { sa 78 }

saMta   MODULE-IDENTITY
        LAST-UPDATED    "201611100000Z"
        ORGANIZATION    "Cisco Inc."
        CONTACT-INFO    "vveeraga@cisco.com"
        DESCRIPTION
            "saMtaDevLCSSignalingSupport controls the LCS Signaling."

        -- History
        REVISION "201611100000Z"
        DESCRIPTION
            "Initial release of reduced-set module for releases based on BFC 5.7.x."

        ::= { saVoip 3 }
        
        
-- MTA Device
saMtaDevice   OBJECT IDENTIFIER ::=  { saMta 1 }
saMtaDevOffHookWarnTOBusy OBJECT-TYPE
    SYNTAX INTEGER {
        disabled(0),
        enabled(1)       
        }
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
        "This object configures whether an endpoint should ring off-hook warning tone. 
		 When this feature is disabled(0), Endpoint should ring off-hook warning tone.
		 When this feature is enabled(1),  Endpoint should ring busy tone instead of off-hook warning tone.
		 The default value of this object is disabled(0)."
    DEFVAL { 0 }
    ::= { saMtaDevice 61 }

-- ==========================
-- ENDPOINT TABLE STARTS HERE
-- ==========================

saMtaEndPointTable   OBJECT-TYPE
    SYNTAX        SEQUENCE OF SaMtaEndPointEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
       "This table describes the MTA EndPoint
        Volume configuration. "
   ::=  { saMta 2 }

saMtaEndPointEntry  OBJECT-TYPE
    SYNTAX        SaMtaEndPointEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        " List of attributes for a single MTA endpoint interface."
    INDEX { ifIndex }
    ::= { saMtaEndPointTable 1 }

SaMtaEndPointEntry  ::= SEQUENCE {
    saMtaEndPntHookFlashMinTime         INTEGER,
    saMtaEndPntHookFlashMaxTime         INTEGER,
    saMtaEndPntStatePhysical            INTEGER,
    saMtaEndPntStateLogical             INTEGER
    }

saMtaEndPntHookFlashMinTime OBJECT-TYPE
    SYNTAX INTEGER (40..2000)
    UNITS         "milliseconds"
    MAX-ACCESS    read-write
    STATUS        current
    DESCRIPTION
        "Shortest onhook time at which hook-flash event will be detected, in miliseconds.
         Breaks in loop current with shorter duration are assumed to be noise and are ignored."
    ::= { saMtaEndPointEntry 1 }

saMtaEndPntHookFlashMaxTime OBJECT-TYPE
    SYNTAX INTEGER (100..2000)
    UNITS           "milliseconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
        "Longest onhook time at which hook-flash event will be detected, 
         in miliseconds. If onhook time is longer then saMtaHookFlashMaxTime, 
         hang up event will be detected."
    ::= { saMtaEndPointEntry 2 }

saMtaEndPntStatePhysical OBJECT-TYPE
    SYNTAX INTEGER {
        onHook(1),
        offHook(2)
    }
    MAX-ACCESS 	  read-only
    STATUS        current
    DESCRIPTION	
        "Returns the physical state of the end point. 
         1: No phones attached or one or more phones are attached and 
            on-hook 
         2: One or more phones are attached and off-hook" 
    ::= { saMtaEndPointEntry 6 }

saMtaEndPntStateLogical  OBJECT-TYPE 
    SYNTAX INTEGER { 
        connectedIdle(1), 
        disconnected(2),
        inCallVoice(3),
        inCallData(4)
    } 
    MAX-ACCESS read-only 
    STATUS current 
    DESCRIPTION 
        "Returns the logical state of the end point. 
         1: endpoint is connected to CMS and not in call
         2: endpoint is not connected to CMS
         3: endpoint is in voice mode call
         4: endpoint is in data mode (fax/modem) call"
    ::= {  saMtaEndPointEntry 7 } 
END